Yahya, M Farid and Ab Malek, Muhammad Faiz and Mat Dan, Reduan (2023) Investigation into magnetic drive sealless pump failure 3 flare gas recovery unit (FGRU). PLATFORM - A Journal of Engineering, 7 (1). pp. 30-33. ISSN 2636-9877
Text
0120031122023656.PDF Download (813kB) |
Abstract
Failure investigation was conducted on magnetic drive centrifugal sealless pumps that had only been operating for six months and were already struggling to rotate. It was discovered that hydrocarbon sludge and other debris had blocked the lubricating channel, which was meant to provide pathways for cooling and lubricating the pump's inner magnetic and containment shell. Further investigation revealed that service water had contaminated the process fluid, precipitating calcium carbonate upon contact with the amine solution and clogging the flushing line. An additional duplex strainer was installed on the repaired pumps, and adequate precautions were taken to prevent water contamination.
Item Type: | Article |
---|---|
Uncontrolled Keywords: | Cleanliness, Internal flushing, Contamination, Clogging, Duplex strainer |
Divisions: | Faculty of Mechanical Engineering |
Depositing User: | Sabariah Ismail |
Date Deposited: | 02 Jul 2024 11:07 |
Last Modified: | 02 Jul 2024 11:07 |
URI: | http://eprints.utem.edu.my/id/eprint/27283 |
Statistic Details: | View Download Statistic |
Actions (login required)
View Item |