Jali, Mohd Hafiz and Jahava, Marlina and Abdul Rahman, Muhammad Azizi and Md Johari, Md Ashadi and Ahmad, Aminah and Mohd Yusof, Haziezol Helmi and Johari, Siti Halma and Harun, Sulaiman Wadi and Thokchom, Siddharth (2024) PVA coated glass substrates for acetone detection. Journal Of Advanced Research In Applied Sciences And Engineering Technology, 33 (2). pp. 187-197. ISSN 2462-1943
Text
0195007112023415.PDF Download (570kB) |
Abstract
Technology advancement in photonics has progressively tailor human need in healthcare industries. Inventing a new medical device or application for the mental and health sectors have make disease diagnosis easier. Without prevention, the number of sufferers may rise quickly. Studies have identified a way to diagnose diabetes illness by measuring a person's acetone level. The existing blood test have inferiority in term of invasive and dangerous if not handled properly. In this report, acetone concentration has been detected using a simple, low-cost Polyvinyl Alcohol (PVA) coated glass substrate platform as a potential diagnosis tool for diabetes patient. Based on the experiment results, the proposed sensor exhibits exceptional sensing performances for acetone detection in term of sensitivity, linearity, repeatability, stability and hysteresis.
Item Type: | Article |
---|---|
Uncontrolled Keywords: | Acetone, Polyvinyl alcohol PVA, Glass substrate, Diabetes |
Divisions: | Faculty of Electrical Engineering |
Depositing User: | Norfaradilla Idayu Ab. Ghafar |
Date Deposited: | 04 Oct 2024 15:31 |
Last Modified: | 04 Oct 2024 15:31 |
URI: | http://eprints.utem.edu.my/id/eprint/27628 |
Statistic Details: | View Download Statistic |