Linear and Rotary Infrared Scan System for Measuring Circumference

Miskon, Muhammad Fahmi and Md Sani, Zamani and Jamaluddin, Mohd Herman (2011) Linear and Rotary Infrared Scan System for Measuring Circumference. In: MUiCET 2011, 2011, Batu Pahat, Johor.

[img] PDF
Mucet_Tree_(1).pdf
Restricted to Registered users only until 13 November 2014.

Download (548kB) | Request a copy

Abstract

This paper presents the design and development of new circumference measurement methods. Three methods namely the Digital Linear Scan (DLS), Analog Linear Scan (ALS) and Analog Rotary Scan (ARS) were designed and develop using the combinations of hardware of infrared sensors and stepper motors with different novel algorithms to control the motion of the system. Experiments were conducted to measure the accuracy of the proposed methods using standard size PVC pipes. The results shows that the accuracy of ALS, DLS and ARS to be 81.6245%, 99.2245% and 79.9673%.

Item Type: Conference or Workshop Item (Paper)
Subjects: T Technology > TK Electrical engineering. Electronics Nuclear engineering
Divisions: Faculty of Electrical Engineering > Department of Mechatronics Engineering
Depositing User: En Zamani Md. Sani
Date Deposited: 18 Nov 2013 04:24
Last Modified: 28 May 2015 04:09
URI: http://eprints.utem.edu.my/id/eprint/10205
Statistic Details: View Download Statistic

Actions (login required)