Real-Time Microwave Moisture Measurement Of Nickel Ore In Conveyor Applications

Win Adiyansyah, Indra and Nurulhalim, Hassim (2016) Real-Time Microwave Moisture Measurement Of Nickel Ore In Conveyor Applications. Jurnal Teknologi, 78 (6). pp. 111-115. ISSN 0127-9696

[img] Text
Real-Time Microwave Moisture Measurement Of Nickel Ore In Conveyor Applications.pdf - Published Version

Download (641kB)

Abstract

There are many advantages of knowing the moisture content of material in a real-time basis. Moisture content is a crucial parameter that affects material handling. Various technologies have been introduced but only a few were successfully applied for on-line moisture measurement in bulk mineral applications. This paper describes a Random Stratified Sampling Sweeping Microwave technique, moisture content measurement technique that reduce interference, annulling or superimposing signal, which are common errors in moisture measurement using microwave transmission technology. The technique is used for nickel ore running on a belt conveyor exiting the rotary dryer. The experimental results showed regression of 0.85, standard error of 0.18, and accuracy of 0.7wt%.

Item Type: Article
Uncontrolled Keywords: Microwaves; Moisture; Nickel ore
Subjects: T Technology > T Technology (General)
Divisions: Faculty of Engineering Technology > Department of Electronics & Computer Engineering Technology
Depositing User: Mohd Hannif Jamaludin
Date Deposited: 29 Sep 2016 00:06
Last Modified: 12 Sep 2021 19:45
URI: http://eprints.utem.edu.my/id/eprint/17271
Statistic Details: View Download Statistic