Mohamad Haniff , Harun and Khalil Azha, Mohd Annuar and Mohd Firdaus, Mohd Ab Halim and Mohd Hanif, Che Hasan and Mohd Shahrieel, Mohd Aras and Muhamad Faizal, Yaakub (2016) Peltier And Seebeck Efficacy Of Hot And Cold Air System For Portable O-Ref (Oven & Refrigerator) Application. Proceedings of Mechanical Engineering Research Day 2016. pp. 81-82. ISSN 9789670257709
Other
23.PDF - Submitted Version Download (334kB) |
Abstract
The main motivation in using Peltier Module is due to the uniqueness of producing hot and cold air at the same time besides able to generate electricity using Seebeck Effect. The generating system theoretically can recycle the heat loss to produce additional electricity for other usage. The efficacy of this system tested using two types of experimental using Peltier and Seebeck Effect. Both experimental is conducted using 3 specific volumes; 1) 1000cm3; 2) 4000cm3; and 3) 9000cm3. As a result, temperature for heating and cooling systems achieve around 14 – 56oC while the voltage generated around 12V in 50 minutes.
Item Type: | Article |
---|---|
Uncontrolled Keywords: | Seebeck effect; peltier effect; thermo-electric heat pump |
Subjects: | T Technology > T Technology (General) T Technology > TJ Mechanical engineering and machinery |
Divisions: | Faculty of Engineering Technology |
Depositing User: | Nor Aini Md. Jali |
Date Deposited: | 14 Feb 2017 08:35 |
Last Modified: | 18 Jul 2021 21:02 |
URI: | http://eprints.utem.edu.my/id/eprint/18031 |