Improvement of an indoor environmental quality (IEQ) in university healthcare building

Mohd Shah, Mohd Syahrir (2019) Improvement of an indoor environmental quality (IEQ) in university healthcare building. Masters thesis, Universiti Teknikal Malaysia Melaka.

[img] Text (24 Pages)
Improvement Of An Indoor Environmental Quality (IEQ) In University Healthcare Building.pdf - Submitted Version

Download (1MB)
[img] Text (Full text)
Improvement of an indoor environmental quality (IEQ) in university healthcare building.pdf - Submitted Version
Restricted to Registered users only

Download (4MB)

Abstract

Indoor Environmental Quality (IEQ) is important to business, building managers, facilities staffs and employees of particular building because it can contribute both positive and negative impact to the health conditions, comfort feelings, wellbeing and productivity of the building occupants, including health care premises . The Indoor Air Quality (IAQ) is vital to be assessed within hospitals and other health care buildings. The patients and staffs within these establishments can be impacted directly by the quality of air in the building. The main objective of the study is to determine the indoor environment condition of university healthcare building. Physical measurement was conducted using Delta Ohm Thermal Microclimate, IAQ-Calc Indoor Air Quality Meter 7545 and DustTrack II Aerosol Monitor to analyse thermal comfort and indoor air quality as to evaluate the indoor environment quality of the indoor healthcare areas. Physical measurements were conducted with occupancy while subjective measurement was carried out through self-administered questionnaire surveys. Result shows that the indoor air temperature and air velocity not complied to MS 1525 standard. While, the concentration of PMl0 inside the building also not complied to DOSH standard. The Predicted Mean Vote (PMV) and Predicted Percentage of Dissatisfied (PPD) not complied to ASHRAE standard . Based on the subjective measurement, only 26.3% feeling comfort while being inside the building. With regards to the findings, indoor environment quality (IEQ) improvement measures are proposed to enhance the IEQ level of the building. The study suggested that the temperature of the air conditioners should be set at 21oc with air velocity of 1,144.2 cfm, and the fresh air also must be supplied to the areas.

Item Type: Thesis (Masters)
Uncontrolled Keywords: Indoor air pollution, Industrial hygiene
Subjects: T Technology > T Technology (General)
T Technology > TD Environmental technology. Sanitary engineering
Divisions: Library > Tesis > FKM
Depositing User: Mohd Hannif Jamaludin
Date Deposited: 31 Dec 2019 10:29
Last Modified: 13 Jun 2022 09:56
URI: http://eprints.utem.edu.my/id/eprint/23968
Statistic Details: View Download Statistic

Actions (login required)

View Item View Item