Azraai, Shamsul Bahari and Sulaiman, Mohd Yusoff and Din, Abdul Talib and Mohlis, Mohd Adib Muizzuddin (2009) Heat Transfer in An Array of Staggered Tube Using CFD Method. In: Proceeding for 2010, 2nd International Conference on Applications and Design in Mechanical Engineering 2009 (iCADME 2009). Proceeding of International Conference on Applications and Design in Mechanical Engineering 2009 (iCADME 2009), 4 (7172). Penerbit Unimap, Unimap Perlis, Malaysia. ISBN 978-967-5415-07-4

[img] Text
iRepository_at_Perpustakaan_UniMAP_Heat_transfer_in_an_array_of_staggered_tube_using_CFD_method.htm

Download (16kB)

Abstract

Heat exchangers are found in numerous industrial applications such as steam generation in aboller or cooling in the coll of an air conditioner. Heat tranfer in flow across tube bank is importance in designing of heat exchanger. there are two types of arrangement of tube banks, such as in-kine and staggered maner and are characterized by the dimensionless transverse and longitudinal pitches. CFD simulation codes ANSYS CFX software is used to investigated the heat flow across an array of staggered tuibe at three different aspect pitch ratios. The working fluids used are air and water. The flow and beat transfer characteristic of a staggered tube a nearly the same of a single cylinde/tube. The first row characteristic is usually the same as a single tube. But for the second row and so on, the cherectieristic are depend on the rows that's come first. for a single tube actually there are two boundry layers which occur at front of the tube and the back of the tube. laminar boundry layer alwas developed at the front while turbulent at the back. Several geometry. The other parameters such as the flud velocity and temperature are also defined accoding to the previous research. With these parameters th 3-D simulation has been done using CFX software. The results obtained are in terms of velocity, temperature and pressure profile. From the investigation, the lower value of potch ratio is found to give better heat tranfer rate. When the pitch value is decreased, the pressure drop will rise and thus will increace the heat transfer rate.

Item Type: Book Chapter
Uncontrolled Keywords: CFD, CFX, In-Line and Staggered Tube
Subjects: T Technology > T Technology (General)
Divisions: Faculty of Mechanical Engineering > Department of Design and Innovation
Depositing User: Assoc. Prof. Ir. Dr. Abdul Talib Din
Date Deposited: 26 Jul 2013 01:40
Last Modified: 27 Jul 2023 15:41
URI: http://eprints.utem.edu.my/id/eprint/8225
Statistic Details: View Download Statistic

Actions (login required)

View Item View Item